Green computing is the study and practice of using computing resources efficiently. The primary objective of such a program is to account for the triple bottom line, an expanded spectrum of values and criteria for measuring organizational (and societal) success. The goals are similar to green chemistry; reduce the use of hazardous materials, maximize energy efficiency during the product's lifetime, and promote recyclability or biodegradability of defunct products and factory waste.
Modern IT systems rely upon a complicated mix of people, networks and hardware; as such, a green computing initiative must be systemic in nature, and address increasingly sophisticated problems. Elements of such as solution may comprise items such as end user satisfaction, management restructuring, regulatory compliance, disposal of electronic waste, telecommuting, virtualization of server resources, energy use, thin client solutions, and return on investment (ROI).
Contents |
In 1992, the U.S. Environmental Protection Agency launched Energy Star, a voluntary labeling program which is designed to promote and recognize energy-efficiency in monitors, climate control equipment, and other technologies. This resulted in the widespread adoption of sleep mode among consumer electronics. The term "green computing" was probably coined shortly after the Energy Star program began; there are several USENET posts dating back to 1992 which use the term in this manner.[1] Concurrently, the Swedish organization TCO Development launched the TCO Certification program to promote low magnetic and electrical emissions from CRT-based computer displays; this program was later expanded to include criteria on energy consumption, ergonomics, and the use of hazardous materials in construction.[2]
Many governmental agencies have continued to implement standards and regulations that encourage green computing. The Energy Star program was revised in October 2006 to include stricter efficiency requirements for computer equipment, along with a tiered ranking system for approved products.[3][4] The European Union's directives 2002/95/EC (RoHS), on the reduction of hazardous substances, and 2002/96/EC (WEEE) on waste electrical and electronic equipment required the substitution of heavy metals and flame retardants like PBBs and PBDEs in all electronic equipment put on the market starting on July 1, 2006. The directives placed responsibility on manufacturers for the gathering and recycling of old equipment (the Producer Responsibility model).[citation needed]
There are currently 26 US States that have established state-wide recycling programs for obsolete computers and consumer electronics equipment[5]. The statutes either impose a fee for each unit sold at retail (Advance Recovery Fee model), or require the manufacturers to reclaim the equipment at disposal (Producer Responsibility model).
| This section includes a list of references or external links, but its sources remain unclear because it lacks in-text citations. You can improve this article by introducing more precise citations where appropriate. (August 2008) |
Computer virtualization is the process of running two or more logical computer systems on one set of physical hardware. The concept originated with the IBM mainframe operating systems of the 1960s, but was commercialized for x86-compatible computers only in the 1990s. With virtualization, a system administrator could combine several physical systems into virtual machines on one single, powerful system, thereby unplugging the original hardware and reducing power and cooling consumption. Several commercial companies and open-source projects now offer software packages to enable a transition to virtual computing. Intel Corporation and AMD have also built proprietary virtualization enhancements to the x86 instruction set into each of their CPU product lines, in order to facilitate virtualized computing.
| This section includes a list of references or external links, but its sources remain unclear because it lacks in-text citations. You can improve this article by introducing more precise citations where appropriate. (August 2008) |
The Advanced Configuration and Power Interface (ACPI), an open industry standard, allows an operating system to directly control the power saving aspects of its underlying hardware. This allows a system to automatically turn off components such as monitors and hard drives after set periods of inactivity. In addition, a system may hibernate, where most components (including the CPU and the system RAM) are turned off. ACPI is a successor to an earlier Intel-Microsoft standard called Advanced Power Management, which allows a computer's BIOS to control power management functions.[citation needed]
Some programs allow the user to manually adjust the voltages supplied to the CPU, which reduces both the amount of heat produced and electricity consumed. This process is called undervolting. Some CPUs can automatically undervolt the processor depending on the workload; this technology is called "SpeedStep" on Intel processors, "PowerNow!"/"Cool'n'Quiet" on AMD chips, LongHaul on VIA CPUs, and LongRun with Transmeta processors.
Desktop computer power supplies (PSUs) are generally 70–75% efficient[10], dissipating the remaining energy as heat. An industry initiative called 80 PLUS certifies PSUs that are at least 80% efficient; typically these models are drop-in replacements for older, less efficient PSUs of the same form factor.[11] As of July 20, 2007, all new Energy Star 4.0-certified desktop PSUs must be at least 80% efficient.[12]
Smaller form factor (e.g. 2.5 inch) hard disk drives often consume less power than physically larger drives.[13][14]
Unlike hard disk drives, solid-state drives store data in flash memory or DRAM. With no moving parts, power consumption may be reduced somewhat for low capacity flash based devices.[15][16][17] Even at modest sizes, DRAM based SSDs may use more power than hard disks, (e.g., 4GB i-RAM uses more power and space than laptop drives). Flash based drives are generally slower for writing than hard disks.[17]
A fast GPU may be the largest power consumer in a computer.[18]
Energy efficient display options include:
LCD monitors typically use a cold-cathode fluorescent bulb to provide light for the display. Some newer displays use an array of light-emitting diodes (LEDs) in place of the fluorescent bulb, which reduces the amount of electricity used by the display.[19]
Computer systems that have outlived their particular function can be repurposed, or donated to various charities and non-profit organizations[20]. However, many charities have recently imposed minimum system requirements for donated equipment.[21] Additionally, parts from outdated systems may be salvaged and recycled through certain retail outlets[22][23] and municipal or private recycling centers.
Recycling computing equipment can keep harmful materials such as lead, mercury, and hexavalent chromium out of landfills, but often computers gathered through recycling drives are shipped to developing countries where environmental standards are less strict than in North America and Europe[24]. The Silicon Valley Toxics Coalition estimates that 80% of the post-consumer e-waste collected for recycling is shipped abroad to countries such as China, India, and Pakistan.[25]
Computing supplies, such as printer cartridges, paper, and batteries may be recycled as well.[26]
Teleconferencing and telepresence technologies are often implemented in green computing initiatives. The advantages are many; increased worker satisfaction, reduction of greenhouse gas emissions related to travel, and increased profit margins as a result of lower overhead costs for office space, heat, lighting, etc. The savings are significant; the average annual energy consumption for U.S. office buildings is over 23 kilowatt hours per square foot, with heat, air conditioning and lighting accounting for 70% of all energy consumed. [27] Other related initiatives, such as hotelling, reduce the square footage per employee as workers reserve space only when they need it. Many types of jobs -- sales, consulting, field service -- integrate well with this technique.
Voice over IP (VoIP) reduces the telephony wiring infrastructure by sharing the existing Ethernet copper (a toxic metal). VoIP and phone extension mobility also made Hot desking and more practical.
|
|||||||||||